EXTRACTED TEXT FROM: New outdoor waterproof laser beam light(英文）.docx

New outdoor waterproof laser beam light
Lightweight design



Instructions for Use

Catalogue
1. Precautions and installation
1
1.1 Declaration
1
1.2 Maintenance
1
1.3 Product precautions
1
1.4 Product Introduction
1
1.5 Connecting Signal Cables
2
1.6 Lighting Installation
2
2. Control panel
4
2.1 Key Instructions
4
2.2 Main Menu
5
2.2.1 Settings
5
2.2.2 Manual
5
2.2.3 Information
6
2.2.4 Factory
7
3. Channel function
8
3.1
 Channel Table
8
4. Common Faults
 11


1. Precautions and installation Precautions and installation
Declaration
Thank you for choosing our products! 8, This product is in good condition and the package is complete when it leaves the factory. For your safe and effective use of this product, before you use this product, please read this manual carefully and completely. This manual contains important information for installation and use. Please install and operate according to the requirements of the manual. At the same time, please keep this manual properly for use at any time. Our company does not assume all responsibility for damage to lamps or other performance due to individuals not operating in accordance with the instructions during installation, use and maintenance.
This manual is subject to technical changes without prior notice.

Maintenance
Disconnect the power supply before performing maintenance.
This lamp should be kept dry and avoid working in wet environment.
Intermittent use will effectively extend the life of the luminaire.
In order to obtain good ventilation and lighting effects, pay attention to cleaning the fan and fan net as well as the lens often.
Do not rub the luminaires housing with organic solvents such as alcohol to avoid damage.

Product precautions
This light fixture is for professional use only.
Ensure that the power supply voltage matches the required power supply voltage of the equipment before operation.
Do not place this product in a place that is easy to loose or shake.
During use, if the lamp is abnormal, stop using the lamp in time.
In order to ensure the service life of the product, this product should not be placed in a humid or leaking place, and should not work in an environment where the temperature exceeds 60 degrees.
When the lamp is used, the power supply voltage change should not exceed ±10%, the voltage is too high, will shorten the life of the lamp, the voltage is too low, it will affect the light color of the lamp.
After the power off, it takes 20 minutes to use the lamp to cool down fully before it can be used again.
The rotating parts of the lamp and the attaching accessories must be checked regularly, and the loosening and shaking should be reinforced in time to prevent accidents.
In order to ensure the normal use of this product, please read this instruction carefully.

Product Description
Total Power: 300W
Light Source Type: Laser Light Source
Voltage: AC 200V~240V/50~60Hz;
Color disk: each color disk is composed of a color plate + white light;
Pattern plate: a pattern effect;
540° pan, 270° tilt.
Overheat protection;
Control mode: DMX512/ master-slave/automatic;
IP66 protection level                    

Signal cable connection
Light fixtures feature standard DMX input and output 3-core or 5-core XLR sockets. Use a twisted-pair signal cable shielded specifically for DMX 512; The signal line is generally connected at a distance of 150 meters, and the DMX512 signal amplifier must be added for long distance signal transmission.
Use a shielded twisted-pair signal line from the DMX outlet of the controller to the DMX input of the first device, and from the DMX outlet of the first device to the DMX input of the second device, and so on, until all the lamps are connected. Then install a terminal plug on the last 3-pin connector of the connecting luminaire output on each line. (Weld a 4/1W, 120Ω resistor between the 2 and 3 pins of the 3-pin pin cannon plug).

Important: The wires should not touch each other or the metal housing.


Figure 1 Schematic diagram of DMX signal wire connection
The calculation method of the starting address code of the lamp:
The initial address code of the current luminaire is equal to (the initial address code of the previous luminaire)+(the number of channels of the luminaire)
1: The initial address code value of the first luminaire A001.
2: The basic channel number of the controller should be greater than or equal to the total number of channels used by the luminaire.
3: Note: when using any controller, each luminaire should have its own starting address code, if the first luminaire's starting address code is set A001, the number of luminaire channels is 16CH; Then the starting address code of the second lamp is set to A017; The starting address code of the third lamp is set to A033; And so on,(this setting also needs to be determined according to different consoles)

Luminaire installation
Luminaires can be placed horizontally, hung diagonally, and hung upside down. Be sure to pay attention to the installation method when hanging diagonally and upside down. 
As shown in Figure 2, before positioning the luminaire, it is necessary to ensure the stability of the installation site. During the reverse hanging installation, it is necessary to ensure that the luminaire does not fall down on the support frame. It is necessary to use the safety rope to pass through the support frame and the luminaire handle for auxiliary hanging to ensure safety. Prevent the luminaire from falling and sliding.
During the installation and commissioning of the lamp, pedestrians are prohibited from passing under the lamp, and the safety rope is regularly checked for wear and whether the hook screws are loose.
If the hanging installation is not stable, resulting in the fall of the lamp and all the consequences, our company does not assume any responsibility.

Figure 2 Schematic diagram of the lamp hanging upside down










1.Control panel

2.1 Key Instructions


Figure 3 Schematic diagram of key description on the panel
The following takes "Modify DMX address code" as an example to describe the use of keys:
1, if the current is not the main interface, press the "left" key (one or more times) to return to the main interface
2, in the home screen, press the "up" key or "down" key to select the "Settings" button
3. Press the "OK" key to enter the "Settings" interface
4, in the "Settings" interface, press the "up" key or "down" key to select "DMX address"
5, press the "OK" key to enter the editing state
6, press the "up" key or "down" key to modify the DMX address code
7, press the "OK" key to exit the editing state







2.2 Menu Description
      

Figure 4 Schematic diagram of main menu

2.2.1 Settings
Options
Instructions
Run
DMX
Slave state: Receives DMX signals from the console or host

Bootstrap
Host status: Self-drive and send DMX signal to slave

Voice Control

Scene setting


DMX address
1-512
Press "OK" to enter the editing state. At this time, the hundreds digit is selected, and press the "up" and "down" keys to change the address code. Press the "OK" key again to select the tens edit. Press "OK" again to select the ones edit. Press again to exit the editing state
Bulb
Off
Off Bubble

On
Bright Bubble
Motor reset

Off


On
Light fixture reset
Channel

Standard 16CH
Standard 16 channel mode

Extended 24CH
Expand 24 channel mode
Language
English
Set to English interface

Chinese
Set to the Chinese interface
Screen flip

Off
Front display

On
Screen inverted display
X Inversion

Off


On
X Motor direction rotation 540 degrees
Y reversal

Off


On
Y Turn the motor 270 degrees in the direction
XY switching

Off


On
Channel for switching XY axes (including fine tuning)
XY encoder

On
Use an encoder (optocoupler) to judge out of step and automatically correct the position

Off
Correct position without using an encoder (optocoupler)
DMX signal

Hold
Continue running in its original state

Reset
Turn the motor back and stop running
Turn on bright bubble
Off


On
Bright bubble after turning on
Linear color

On
The color wheel changes linearly

Off
Color wheel nonlinear change, half-color change
Clear scene data

Press the "OK" key to clear scene data
Restore default
On


Off
Press "OK" to see the confirmation dialog box, press "OK" again to restore the default Settings

Scene Setup Instructions
Options
Instructions
Scene selection
01-20
Select Scenario 1- Scenario 20 for programming
Scene time
0-255.
Set the running time of the current scene, up to 255 seconds
Scene Run
On
The default is on, which will be executed during auto run, and if it is set to interrupt, it will skip the current scene and run the next scene

Off

Step 1: Color
0-255.
Set console values 0-255
2 Cut light/strobe
0-255.

3 Dimmer
0-255.

4 Pattern plates
0-255.

5...
0-255.

6...
0-255.





2.2.2 Manual control
This interface is used to control the current luminaire (does not receive DMX signals), corresponding to the channel. Refer to the channel table for details
Options
Instructions
1CH.
0 ~ 255
Press "OK" to enter the editing state. At this time, the hundreds digit is selected, and press the "up" and "down" keys to change the channel value. Press the "OK" key again to select the tens edit. Press "OK" again to select the ones edit. Press again to exit the editing state
...
0 ~ 255

15CH.
0 ~ 255

...
0 ~ 255



2.2.3 Information

Options
Instructions
Ver

Show software version
DIS

Display board software version
MT

Motor board software version
Time information
Time information Steps 1 Total brightening bubbles
2. Total use
Record the cumulative bright-bubble time
Record the lighting time
System error

If the red ERR indicator is bright, it indicates that the lamp is running incorrectly. You can go to the subinterface to view the details. After viewing, you can press the "Clear" button to clear the error record
Blower speed

Displays the current blower speed
Hall Status
0000
0 when magnetic is detected, 1 otherwise
The X-axis encodes the disk step value
0000
The number of steps should increase for forward travel and decrease for reverse travel. The number should be normal every time you reach the same point
The Y-axis encodes the disk step value
0000
The number of steps should increase for forward travel and decrease for reverse travel. The number should be normal every time you reach the same point
Permission Duration

9999 No encryption; Other values can be used with encryption

A. Error message description

Common Error Messages
Instructions
MT board connection failed
Motor board not responding. There is a problem with the serial communication line connecting the display board to the motor board, or there is a problem with the motor board.
X-axis reset failed
There is a problem with the X-axis photoelectric switch, or the X-axis motor or motor board
Y-axis reset failed
Y-axis photoelectric switch, or Y-axis motor or motor board problem
X-axis Hall error
X-axis Hall, or a problem with the motor board
Y-axis Hall error
Y-axis Hall, or a problem with the motor board
Color disk reset failed
Color disk Hall, or there is a problem with the color disk motor
The pattern plate failed to reset
Pattern plate Hall, or pattern plate motor has a problem
The focus reset failed
Focusing Hall, or a problem with the focusing motor
Bulb control failure
Failure to light or extinguish bubbles, lamplighter or bulb problem

2.2.4 Factory
Calibrate
Fan adjustment (test)
Fan regulation


Blower speed


Wind speed low off Bubble on/off

Data download
After changing the display board, download the calibration data of the original display board from the motor board

X
After entering the sub-interface, the reset position of the motor such as X axis and Y axis can be adjusted to make up for the error on the hardware installation. The adjustment range is -128~+127, and +0 indicates no adjustment.

Y


Colors


Gobo


Focus


Dimming


Prism 1 Zero


Prism 1 Stroke


Prism 2 Zero


Prism 2 Stroke


Frost white light


Frost stroke


Colorful mirror stroke


Zeroing
close


On, the data is restored to default values

X Hall
Off, X Hall report wrong off


On, X Hall reports the wrong off

Y Hall
Off, Y Hall reports wrong off


On, Y Hall reports an error

Half power
Off, no half power function


On, with half power function
Channel function
3.1
 Channel Table
Channels
24 channel mode
1
Color Wheel
2
Shutter
3
Dimming
4
Gobo
5
Prism 1
6
Prism 1 Rotation
7
Prism 2
8
Prism 2 Rotation
9
Focus
10
X
11
X Fine
12
Y
13
Y Fine
14
XY Speed
15
Frost /Colorful
16
Lamp& Reset
17
LED_Dimming
18
LED_Shutter
19
LED_Red
20
LED_Green
21
LED_Blue
22
LED_Color macro
23
LED_Scene
24
LED_Scene Speed



Channel parameter values (full version) :
Channel
Features
Channel values
Effects
1
Color 
000-004
005 -009
010 - 014
015 - 019
020 - 024
025 - 029
030 - 034
035 - 039
040 - 044
045 - 049
050 - 054
055 - 059
060 - 064
065 - 069
070 - 074
075 - 079
080 - 084
085 - 089
090 - 094
095 - 099
100 -104
105 -109
110 -114
115 -119
120 -124
125 -129
130 -134
135 -139
140 -144
145 -149
150 -200
201- 255
White Light
White light + Color 1
Color 1
Color 1+ Color 2
Color 2
Color 2+ Color 3
Color 3
Color 3+ Color 4
Color 4
Color 4+ Color 5
Color 5
Color 5+ Color 6
Color 6
Color 6+ Color 7
Color 7
Color 7+ Color 8
Color 8
Color 8+ Color 9
Color 9
Color 9+ Color 10
Color 10
Color 10+ Color 11
Color 11
Color 11+ Color 12
Color 12
Color 12+ Color 13
Color 13
Color 13+Color 14
Color 14
Color 14+white light
Backward running water (from fast to slow)
Forward flow (slow to fast)
2
Shutter
000-003
004-103
104-107
108-207
208-212
213-251
252-255
Light brake open
Stroboscopic from slow to fast           
Light gate on → (controlled by dimmer channel)
Pulse stroboscopic from slow to fast 
Light gate open → (controlled by dimmer channel)
Random strobe from slow to fast 
Light gate open → (controlled by dimming channel)
3
Dimming
000-255
Dark to light
4
Gobo
000 - 004
005 - 009
010 - 014
015 - 019
020 - 024
025 - 029
030 - 034
035 - 039
040 - 044
045 - 049
050 - 054
055 - 059
060 - 064
065 - 069
070 - 074
075 - 079
080 - 084
085 - 089
090 - 094
095 - 099
100 - 104
105 - 109
110 - 114
115 - 119
120 - 124
125 - 129
130 - 134
135 - 139
140 -144
145 -149
150 - 200
201 - 255
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Gobo 8
Gobo 9
Gobo 10
Gobo 11
Gobo 12
Gobo 13
Gobo 14
Gobo 15
Gobo 1 Shake(from slow to fast)
Gobo 2 Shake(from slow to fast)
Gobo 3 Shake(from slow to fast)
Gobo 4 Shake(from slow to fast)
Gobo 5 Shake(from slow to fast)
Gobo 6 Shake(from slow to fast)
Gobo 7 Shake(from slow to fast)
Gobo 8 Shake(from slow to fast)
Gobo 9 Shake(from slow to fast)
Gobo 10 Shake(from slow to fast)
Gobo 11 Shake(from slow to fast)
Gobo 12 Shake(from slow to fast)
Gobo 13 Shake(from slow to fast)
Gobo 14 Shake(from slow to fast)
Gobo 15 Shake(from slow to fast)
Positive flowing water (from fast to slow)
Backward flow (slow to fast)
5
Prism 1
000-127.
128-255.
None
Prism 1 Cut in
6
Prism 1 Rotate
000-127.
128-190.
191-192.
193-255.
Prism 1 Angle adjustment
Reverse rotation (from fast to slow)
Stop
Forward rotation (slow to fast)
7
Prism 2
000-127.
128-255.
None
Prism 1 Cut in
8
Prism 2 Rotate
000-127.
128-190.
191-192.
193-255.
Prism 1 Angle adjustment
Reverse rotation (from fast to slow)
Stop
Forward rotation (slow to fast)
9
Focus
000-255.
Gobo clarity from far to near
10
X
000-255.
Horizontal 540 degree scan
11
X Fine
000-255.
Horizontal 1.2 degree fine tuning
12
Y
000-255.
Vertical 270 degree scan
13
Y Fine
000-255.
Vertical 1.2 degree fine trim
14
XY Speed
000-255.
Speed from fast to slow
15
Frost & Colorful
000-127.
128-191.
192-255.
None
Colorful cut in
Frost cut in
16
Lamp& Reset
000-025.
026-050.
061-085.
100-109.
200-209.
251-255.
Safe
Reset Effect
Reset XY
Lamp Off
Lamp Off
Reset All 
17
LED_Dimming
000-255.
Dark to light
18
LED_Shutter
000-003.
004-255.
Light brake open
Light brake on → (controlled by light with 17 channel)
19
LED_Red
000-255.
0-100% from dark to light
20
LED_Green
000-255.
0-100% from dark to light
21
LED_Blue
000-255.
0-100% from dark to light
22
LED_Color macro
0-255


23
LED_Scene
000-031
032-255

24
LED_Scene speed
000-255



Common fault
According to some common faults, the corresponding solutions are put forward. Any problems that cannot be solved should be dealt with by professionals. Disconnect the light fixture from the power supply before maintaining it.
The light bulb is not working
Check that the voltage that matches the light fixture is installed;
Check whether the lamp power supply connection or control switch is in poor contact;
Check whether the power supply is insufficient;
Check that the DMX512 controller is sending instructions.

The light fixture does not accept control from the console after normal reset
Check luminaire digital start address value and function options are correct;
Check whether the connection of the communication control line is correct, the communication line is too long or has been interrupted;
Check whether the control equipment is invalid, check whether the signal amplifier connected to the series is invalid;
Check whether the communication line is too long or other devices interfere with each other;
Optimize wiring, shorten the length of the control signal line, high-voltage and low-voltage lines separate wiring;
Add signal amplifiers;
Signal line using high quality shielded twisted pair wire;
Connect the signal terminal resistor (120 ohms) at the end of the lamp.

Luminaire does not start
Check that the power supply parameters are consistent with the luminaire;
Check the lamps in the long distance transportation process due to extrusion deformation, internal parts vibration, moisture and other reasons, resulting in poor contact
Or fall off.
Please check whether the internal wire integration connector of the lamp has fallen off and is loose.
Check whether the electronic components of the lamp (such as electronic transformer, PCB board, motor control board, etc.) are loose, short circuit and burned out.

When working, the action of the X axis or Y axis of the luminaire is abnormal
Check them one by one by following the previous step;
Check whether the transmission belt corresponding to the X and Y axis direction in the lamp falls off and breaks;
Check whether the data feedback receiver (optocoupler) corresponding to the X and Y directions in the lamp is damaged;
Restart and reset once.